pro clima AEROSANA VISCONN
Coating for air sealing
Product benefits
The text on this page was automatically translated. Minor translation errors are possible. In case of doubt, the original versions (Dutch and French) are correct.
- Reliable air sealing - even for hard-to-reach details
- Bridges joints, cracks, and gaps up to 20mm
- Durable: remains elastic and firm after drying
- For indoor and outdoor use - moisture-variable µd value
- Excellent adhesion to common building materials
Installer benefits
- Blue, turns black after drying
- Spreadable with a brush
- Sprayable with AEROFIXX air pressure gun - even on previously dusty surfaces
- Easier work - also applicable as an airtight primer to improve the surface
- Compatible - with pro clima adhesive tapes
- Plasterable and paintable
Applications
Suitable for:
- Airtight connection floor/wall and wall/ceiling
- Air sealing of unplastered building parts (base block, wall under the water barrier, wall behind hanging toilet, etc.)
- Air sealing of exposed masonry on the outside
- Also suitable for airtight connection of windows/doors with the construction
- Also suitable for fixing surfaces during renovations.
Product details
Installation steps
General installation steps

1. Prepare the subsurface; stir the product
Subsurfaces should be cleaned. An even subsurface is a prerequisite for the use of AEROSANA VISCONN spray film. Fill any breakages, joints or holes before applying it.
Before application from the tin: stir thoroughly.

2a. Cover over defects
Breakages, joints and holes can be covered over with a suitable filler or with CONTEGA SOLIDO SL before AEROSANA VISCONN is sprayed on.
If defects are detected during spraying, these can be covered over with pro clima AEROSANA FLEECE.

2b. Cover over defects
To do this, paint AEROSANA VISCONN onto a piece of fleece, apply the fleece to the defect and spray over it.

3. Apply a spray film (airless spray process)
Apply AEROSANA VISCONN in at least two layers.
Apply the spray film in an even and overlapping manner.
Additional layers may be necessary, depending on the condition of the subsurface.
In the case of a layer thickness of greater than 1 mm, first allow AEROSANA VISCONN to become touch dry and then proceed to add further layers.
Layers of liquid film that are too thick can run off.
Setting of airless sprayer
Pressure: Approx. 150 - 200 bar
Nozzles: 210, 317, 519

4. Use as a primer
Rough or dusty subsurfaces can be prepared for sticking pro clima adhesive tapes to them by using AEROSANA VISCONN.
To do this, apply a seamless layer of spray film.
Note:
The colour of AEROSANA VISCONN changes from blue to black during drying.

5. Stick joints
Once the spray has dried, apply the adhesive tape and gradually stick it in place.
When plastering, please observe the recommendations of the plaster manufacturer for non-absorbent subsurfaces.
A bonding course may be necessary.
Eave refurbishment with AEROFIXX

1. Preparation
Brush off subsurfaces; if necessary, clean with a vacuum cleaner and wipe down.

2. Spray over birdsmouth joints
In the area around the birdsmouth joints, spray over the joints between rafters and the wallplate with a generous amount of sealant so that any movement of components that occurs can be accommodated.

3. Continue along the rest of the eave
Also apply a generous amount of AEROSANA VISCONN / FIBRE below the rafters in the area around the birdsmouth joints.

4. Seal wide joints
Switch the AIRFIXX to line application and completely fill the gap (in this case, between the wallplate and the knee wall) with AEROSANA VISCONN / FIBRE.

5. Spray over the joint
Set the AEROFIXX to spray application and spray over the joint in a generous manner. Apply the sealant to a width of at least 30 mm on the surfaces to be sealed. The layer thickness is sufficient when a textured surface (‘orange peel’) is recognisable.

6. Use as a primer
If required, apply AEROSANA VISCONN /FIBRE as a primer onto timber that the refurbishment vapour control membrane (e.g. DASATOP) will be bonded to subsequently.

7. Stick the joint
After the sealant has fully dried, seal the refurbishment vapour control membrane in an airtight manner using TESCON VANA, for example.
Joints at double collar ties with AEROFIXX

1. Initial situation

2. Preparation
Brush off subsurfaces; if necessary, clean with a vacuum cleaner and wipe down.

3. Check the joint width
Gaps of up to 3 mm can be filled using AEROSANA VISCONN. Use AEROSANA VISCONN FIBRE for wide gaps of up to 20 mm. In this case, the gap must be filled with sealant to a depth of at least half the width of the gap.

4. Set the device
Set the AEROFIXX to line application.

5. Fill the joint
Fill the joint with a sufficient amount of AEROSANA VISCONN / FIBRE.

6. Spray over the joint
Set the AEROFIXX to spray application and spray over the joint in a generous manner. Apply the sealant to a width of at least 30 mm on the surfaces to be sealed. The layer thickness is sufficient when a textured surface ('orange peel') is recognisable.

7. Work on detail features
Areas that are difficult to access can also be sealed conveniently using the spray method.

8. Check the joint
If necessary, seal any gaps with a brush and AEROSANA VISCONN / FIBRE.

9. The finished joint at a double collar tie penetration
Window joint with AEROFIXX

1. Initial situation
Window is installed, window joint has been filled with insulation material.

2. Preparation
Brush off subsurfaces; if necessary, clean with a vacuum cleaner and wipe down.

3. Cut away any excess insulation material
If necessary, cut away any protruding insulation.

4. Apply masking tape to the window frame
When doing this, leave a strip with a width of at least 6 mm free on the frame for subsequent sealing using AEROSANA VISCONN / FIBRE.
Alternatively, remove the joint insulation to a sufficient extent to create a clean surface for a lateral bond to the side of the window frame.

5. Spray on the sealant
Spray a sufficient amount of AEROSANA VISCONN / FIBRE onto the window frame, the joint insulation and the adjacent masonry. Apply the sealant evenly. Cracks and pores must be closed by flooding them. The layer thickness is sufficient when a textured surface (‘orange peel’) is recognisable.

6. Continue around the rest of the window
Bond all four sides of the frame to the masonry using AEROSANA VISCONN / FIBRE.

7. Check the joint
If necessary, seal any gaps with a brush and AEROSANA VISCONN / FIBRE.

8. Interior and exterior use
AEROSANA VISCONN / FIBRE can be used for interior and exterior window joints. The installation method is identical in both cases.

9. Remove the masking tape
Remove the protective masking tape immediately after the window joint is sealed.
Remove any traces of AEROSANA VISCONN / FIBRE from the window frame immediately using a damp cloth.
Window-sealing, airless

1. Cut away protruding foam
Insert the insulating material (loose wool, loose hemp) into the window joint in such a way that is flush with the window frame.
Cut away protruding foam after it has hardened.

2. Clean the subsurface

3. Protect the window with sheeting
Protect the panes of glass and visible parts of the frame against soiling by using masking tape.

4. Spray the lintel and reveals
Apply the required layer thickness of AEROSANA VISCONN in one or two spraying steps.

5. Check the layer thickness
Check the required wet layer thickness of 500 μm using a suitable gauge.

6. Pre-spray the sub-sill flashing
AEROSANA VISCONN is also suitable for use in forming sub-sill flashing.
To do this, first spray the insulation angle fillet in a generous manner.

7. Install the AEROSANA FLEECE sub-sill flashing
Insert the AEROSANA FLEECE into the still-wet AEROSANA VISCONN spray film, ensuring there are no folds or creases.
Carefully finish any corners or raised edges.

8. Spray over AEROSANA FLEECE
The AEROSANA FLEECE is embedded in place by spraying again with AEROSANA VISCONN.

9. Remove the protective sheeting
Remove the stuck-on protective sheeting before AEROSANA VISCONN dries.
Video: Working with the AEROFIXX
Video: Sealing transitions at eaves with AEROFIXX on refurbishment projects
Video: Sealing around double collar ties with AEROFIXX
Video: Sealing around windows/doors with AEROFIXX
Sealing wall-to-floor joints with AEROFIXX

1. Preparation
Brush off subsurfaces; if necessary, clean with a vacuum cleaner and wipe down.

2. Preparation of taped joints between boards, if required
If the gaps between adjacent wood-based panels have been taped using TESCON RAPIC to create airtight seals, this tape should be covered over with short lengths of TESCON VANA in the area close to the floor where a liquid sealant will be applied. The edges of the TESCON VANA must adhere directly onto the wood-based panel here.

3. Spray setting
Set the AEROFIXX to spray application.

4. Spray over the base joint
Spray the wall-to-floor joint area. Apply the sealant to a width of at least 30 mm on the surfaces to be sealed.
The layer thickness is sufficient when a textured surface (‘orange peel’) is recognisable.
General conditions
Cracks that are wider than 3 mm must be taped over, covered with AEROSANA FLEECE or filled in with a suitable filler. Spraying should be carried out at a distance of approx. 15 cm from the subsurface.
Application in a number of layers can be carried out without any need for drying periods between them. Perfect airtightness can only be achieved with a complete AEROSANA VISCONN film with no gaps.
Linear joints: The best coverage is achieved when spraying is carried out in two layers. The spraying jet should be at approx. 60° to the subsurface, spraying away from the installer. The second spraying step should then be carried out in the opposite direction.
Sealing of surface areas: The best coverage is achieved when one layer is first sprayed on horizontally and then sprayed over vertically in a cross pattern.
AEROFIXX application
The AEROFIXX device is connected to a compressor with a suction flow rate of >300 l/min. The pressure should be set to 6 bar. All AEROSANA VISCONN variants in 600 ml foil cartridges can be applied using the AEROFIXX device. You can easily switch between line (bead) application and spray application by turning the spray head.
Airless application
Airless diaphragm or piston pumps can be used. The throughput of this equipment should not be less than 1.8 litres/min. The recommended nozzles for surface application are: 317 to 521 – for detail features: 210. The first digit of the nozzle designation specifies the spray angle in degrees (x 10°), the second and third digits represent the diameter of the nozzle in 0.0xx inches.
The pressure is set to ensure a uniform spray finish that is free of streaks. If streaks are visible beside the spray area, increase the spray pressure. If this does not help, clean or replace the filter. The optimal pressure is around 80-150 bar, depending on the nozzle used. A mesh size of 60 is recommended for the pistol filter.
Stir the material slowly and uniformly before spraying it. Flush the airless device once with clear water and then empty it fully before putting it into service.
AEROSANA VISCONN FIBRE and AEROSANA VISCONN FIBRE white cannot be applied using airless sprayers; in this case, use the AEROFIXX application gun.
Layer thickness and drying
The required minimum layer thickness of 500 μm has been achieved when a seamless, slightly wavy surface (‘orange peel’) is formed on the surface of AEROSANA VISCONN during the spraying process. Cracks and pores in the subsurface must be covered or closed in order to achieve perfect airtightness. This can be done using AEROSANA VISCONN for cracks/pores up to 3 mm, with AEROSANA VISCONN FIBRE up to 8 mm by spraying or flooding.
The thickness should be checked using the measuring gauge at various points across the entire sprayed surface immediately after the last layer of AEROSANA VISCONN has been applied.
AEROSANA VISCONN changes colour from blue to black when it dries. AEROSANA VISCONN white does not change colour.
The moist film is to be protected against moisture (e.g. rain) until it has fully dried.
Immediately after the spraying work has been completed, the airless device is to be cleaned on the outside with water and flushed a number of times until the flushing water is no longer visibly turbid – completely remove any residues of AEROSANA VISCONN. For additional information (e.g. operating instructions), contact the manufacturer of the airless device.
Protective equipment
The air pressure raises airborne dust. For this reason, it is recommended that installers should wear personal protective equipment consisting of a mask, protective glasses and gloves, even in well-ventilated locations.
Application with a brush
All AEROSANA VISCONN variants can be applied using a brush. To ensure efficient working, the width of the brush should be ≥ 50 mm. Check the minimum layer thickness of 500 μm using a measuring gauge.
Storage
If this product has been in storage for a longer period, water (~5%) can be mixed into it to achieve a consistency that is suitable for spraying. Do not dilute the sealant material too much (risk of excessive flow and poor coverage of cracks). Closing the container in an airtight manner and covering it with a thin sheet will help to prevent drying out.
Reference Number | Attributes |
---|---|
1AR01106 | Volume: 10l |

pro clima AEROSANA VISCONN FIBRE
Coating for air sealing, reinforced with fibers