pro clima INTELLO

Moisture-variable and airtight vapor barrier for all fibrous insulation materials in mat and board form

Find a store

Product benefits

The text on this page was automatically translated. Minor translation errors are possible. In case of doubt, the original versions (Dutch and French) are correct.

  • Airtight
  • At least 50 years lifespan and performance, officially documented in ETA-18/1146
  • Unique! INTELLO PLUS and INTELLO achieved respectively 0.00m³/hm² and 0.01m³/hm² air exchanges in the PassiveHouse certificate, making them perfectly airtight 
  • Optimal protection against construction damage and mold - moisture-controlled function promotes maximum drying of the construction 
  • For all fibrous insulation materials - mineral and natural
  • Environmentally conscious - fleece made from 50% recycled polypropylene

Installer benefits

  • Easy to process  
  • Placement markings on the membrane
  • System warranty

Applications

The vapor barrier and airtightness membrane INTELLO PLUS can be used as the inner boundary of thermal insulation:

  • in roof, ceiling, floor, and wall (also for insulation of exterior walls from the inside)
  • when using fibrous insulation: all mineral and natural insulation and blow-in insulation in mat and board form 
  • in residential and commercial buildings of indoor climate class I - III
  • in all rooms, including kitchens and bathrooms
  • in diffusion-open constructions on the outside
  • in diffusion-tight constructions on the outside (e.g., flat roofs…) (according to the pre-made calculation and advice)
  • also on a winter construction site
Project types
Renovation,
New construction
Applications
Internal insulation,
Airtightness
Construction methods
Masonry (or concrete),
Timber construction (timber frame, CLT,...),
Steel frame construction
Construction elements

Product details

Installation Packaging Variants

Installation steps

Installation steps

Afbeelding
Installation steps

1. Install the membranes

Roll out the membrane and fasten it using galvanised staples that are at least 10 mm wide by 8 mm long at intervals of 10-15 cm or, if blown-in insulation is to be installed, 5-10 cm. Install the membrane leaving an additional 4 cm overlap at adjacent building components so that an airtight bond can be applied here subsequently.

Afbeelding
2. Fasten to stud wall frame members

2. Fasten to stud wall frame members

Fastening of membranes to metal frame members on stud wall and ceiling structures using pro clima DUPLEX. Stick the membrane, ensuring that there are no folds or tension. Rub using the PRESSFIX application tool to secure.

Afbeelding
3. Overlap the membranes

3. Overlap the membranes

Allow for an overlap of approx. 10 cm between the membranes. The marking that is printed onto the membrane will serve as a guide here.

Afbeelding
1. Preparation

4. Clean the subsurface

Clean the subsurface (dry and free of dust, silicone and grease) before taping; carry out an adhesion test, if necessary.

Afbeelding
Installation steps

5a. Tape the overlaps

Centre the TESCON VANA system adhesive tape on the overlap and gradually stick it in place, ensuring that there are no folds or tension.

Afbeelding
5b. Rub the adhesive joint firmly

5b. Rub the adhesive joint firmly

Rub the tape firmly using the pro clima PRESSFIX to secure the adhesive bond. Ensure that there is sufficient resistance pressure.

Afbeelding
6. Sealing to smooth, non-mineral subsurfaces …

6. Sealing to smooth, non-mineral subsurfaces …

… (e.g. knee walls made of wood-based panels) should also be implemented using TESCON VANA system adhesive tape. Centre the tape and gradually stick it in place, ensuring that there are no folds or tension. Rub the tape firmly using the pro clima PRESSFIX to secure the adhesive bond.

Afbeelding
2. Sealing to a plastered gable wall

7. Sealing to rough or mineral subsurfaces

Clean the subsurface. Apply a line of ORCON F adhesive sealant of at least d = 5 mm, or more in the case of very rough subsurfaces if necessary. Place INTELLO onto the adhesive bed, leaving slack to allow for expansion. Do not press the adhesive completely flat.

Afbeelding
8a. Alternative: Sealing to mineral subsurfaces

8a. Alternative: Sealing to mineral subsurfaces

Position ORCON MULTIBOND on the subsurface, roll it out and gradually stick it to the subsurface. Gradually remove the release film.

Afbeelding
8b. Sticking the membrane / Rubbing the joint firmly

8b. Sticking the membrane / Rubbing the joint firmly

Apply the membrane onto the adhesive strip, leaving slack for expansion so as to allow for relative motion between components. Rub firmly to secure the adhesive bond using the pro clima PRESSFIX. Ensure that there is sufficient resistance pressure.

Afbeelding
9. Sealing to unplastered subsurfaces

9. Sealing to unplastered subsurfaces

Stick the CONTEGA PV plaster-sealing tape onto INTELLO using self-adhesive strips. Ensure the tape remains in place by using ORCON F at discrete points. First plaster behind the tape, then apply the tape to the wet plasterwork and plaster over it fully.

Afbeelding
Other application situations

10. Masonry gable end wall, creating an airtight joint

Put the vapour check in place. Leave slack for expansion so as to allow for relative motion between components. Remove all release films from CONTEGA SOLIDO SL or CONTEGA SOLIDO IQ. Centre the tape and gradually stick it in place. Rub the tape firmly using the pro clima PRESSFIX to secure the adhesive bond.

To achieve airtightness, plaster over the masonry and sealing tape.

Afbeelding
11a. Sealing to roughly sawn timber

11a. Sealing to roughly sawn timber

Clean the subsurface. Apply a line of ORCON F adhesive sealant of at least d = 5 mm, or more in the case of very rough subsurfaces if necessary. As an alternative, a roll of ORCON MULTIBOND adhesive sealant can be used.

Afbeelding
11b. Sealing to roughly sawn timber

11b. Sealing to roughly sawn timber

Place INTELLO onto the adhesive bed, leaving slack to allow for expansion. Do not press the adhesive completely flat.

Afbeelding
12a. Sealing to plastered chimney (insulated or double-shelled)

12a. Sealing to plastered chimney (insulated or double-shelled)

Seal INTELLO using ORCON F as shown in Figure 7.

Afbeelding
12b. Sealing to plastered chimney (insulated or double-shelled)

12b. Sealing to plastered chimney (insulated or double-shelled)

Then cut into short pieces of TESCON VANA as far as the centre, create corner shapes and then stick in place.

Afbeelding
13. Sealing around pipes and cables

13. Sealing around pipes and cables

Place a KAFLEX or ROFLEX sealing grommet over the cable or pipe and stick to INTELLO. The cable grommets are self-adhesive. Stick the pipe grommets to the membrane using TESCON VANA.

Afbeelding
14. Corner sealing

14. Corner sealing

Guide TESCON PROFECT pre-folded corner sealing tape into the corner while the release film is still in place and stick the first independent adhesive strip. Then remove the release film and stick the second independent adhesive strip.

Afbeelding
15. Battens, interior cladding

15. Battens, interior cladding

Install battens (e ≤ 50 cm) to bear the weight of the insulation, and install interior cladding to provide protection against UV light and other damage.

Afbeelding
16. Quality assurance

16. Quality assurance

It is recommended that airtightness should be checked using a blower door test.

General conditions

Where possible, INTELLO should be installed in such a way that adhesion can be carried out using single-sided adhesive tape on the smooth (printed) side of the sheeting. It should be installed taut and without slack either in parallel with or perpendicular to the supporting structure, e.g. the rafters. In the case of horizontal installation (perpendicular to the supporting structure), the separation distance of the supporting structure is limited to a maximum of 100 cm. After installation, perpendicular battens on the inside at a separation distance of a maximum of 50 cm must be fitted to carry the weight of the insulation material.

If regular tensile loads on adhesive tape bonds are to be expected – for example, due to the weight of the insulation material – when using mat or panel-shaped insulation materials, an additional supporting batten should be fitted over the overlap sealing. When attaching the membranes in the case of mat or panel-shaped insulation materials, a maximum separation distance of 10 to 15 cm applies for the fastening staples, which must be at least 10 mm wide by 8 mm long. The overlaps between the membrane strips must be approx. 8 to 10 cm.

Airtight seals can only be achieved on vapour check (alternate terms: vapour control or retarder) membranes that have been fitted with no folds or creases. Ventilate regularly and systematically to prevent build-up of excessive humidity (e.g. during the construction phase). Occasional, intermittent ventilation is not sufficient to remove large quantities of moisture due to construction work from a building; use a dryer if necessary.

To prevent condensation formation, INTELLO should be sealed and taped in an airtight manner immediately after the installation of the thermal insulation. This particularly applies when working in winter.

Reference Number Attributes
10090 Dimensions: 1.50m x 50m, Version: standard
10091 Dimensions: 1.50m x 20m, Version: standard
Most popular
Afbeelding
pro clima INTELLO PLUS - productfoto
Internal insulation
Airtightness

pro clima INTELLO PLUS

Strong, hydrosafe and airtight vapor barrier for all fibrous insulation materials

More info
Afbeelding
pro clima INTELLO X
Internal insulation
External insulation
Airtightness

pro clima INTELLO X

Hydrosafe, weather- and UV-resistant vapor barrier for fibrous insulation materials in mat and board form

More info
Afbeelding
pro clima INTELLO X PLUS
Internal insulation
External insulation
Airtightness

pro clima INTELLO X PLUS

Strong, hydrosafe, weather- and UV-resistant vapor barrier for all fibrous insulation materials

More info
Afbeelding
pro clima INTELLO conneX
Airtightness

pro clima INTELLO conneX

Vochtvariabele en weerbestendige dampremmende strook

More info

Related products

Afbeelding
naturheld Flex-productfoto
Internal insulation
External insulation
Acoustics

naturheld Flex

Flexible wood fiber insulation mats

More info
Most popular
Afbeelding
pro clima TESCON VANA
Airtightness
Rain, water, and windproof connections

pro clima TESCON VANA

All-round tape with fleece carrier, for indoor and outdoor use

More info
Most popular
Afbeelding
pro clima CONTEGA SOLIDO IQ
Airtightness
Rain, water, and windproof connections

pro clima CONTEGA SOLIDO IQ

Intelligent tape for airtight and driving rainproof sealing around windows and doors, and for connections wi

More info
Most popular
Afbeelding
pro clima ORCON F
Airtightness
Rain, water, and windproof connections

pro clima ORCON F

All-round connection glue for indoor and outdoor use

More info
Afbeelding
pro clima CONTEGA PV
Airtightness

pro clima CONTEGA PV

Plasterable connection strip with reinforcement

More info
Afbeelding
pro clima KAFLEX mono black

pro clima KAFLEX mono black

Zwarte zelfklevende kabelmanchetten voor 1 kabel, Ø 4,8 - 12 mm, voor binnen en buiten

More info
Afbeelding
pro clima ROFLEX
Detail solution

pro clima ROFLEX

Buismanchetten voor binnen en buiten

More info